Mechanical Specifications

Technical Data


Mechanical Specifications
D x W x H in millimeters incl. connectors & fasteners
110 x 31 x 125 mm
Weight in grams
Approx. 120 g
Mounting / Installation
TS35 DIN rail in grounded metal control cabinets
Color
Black
Connectable conductor cross-section
0.25…1.5 mm2 (uninsulated ferrules)
0.25…0.75 mm² (insulated ferrules)
0.25…1.5 mm² (without ferrule)

Table 3: Mechanical Specifications

CAUTION!

  • Risk of destruction
    An operating voltage that exceeds the voltage specified in the technical data will destroy the . Select an operating voltage that is within the voltage range specified in the technical data.

Please provide the text you'd like me to translate. | Electrical Specifications | | | --- | --- | | Power supply (terminal X7)
| 24V DC (1A max.)
| | Power supply potential-free contacts (terminal X4)
| 24V DC (0.3A max.)
| | Output voltage (terminal X1 and X2)
| 5V DC
| | Output voltage (terminal X3)
| 5V DC (0.5A max.)
| | Output voltage (terminal X5 and X6)
| 24V DC
| | Residual ripple | 100mV pp |

Table 4: Electrical Specifications

Interfaces
UART
5V (0.5A max.) Output, 115200 baud, 8N1, no parity
Service UART (3.5mm jack)
3.3V Input, 115200 baud, 8N1, no parity
RS-485
proprietary
Bluetooth
4.0 dual mode
WLAN
802.11b/g/n
Ethernet
100 Mbit/s

Table 5: Interfaces

Storage Capacity
Sensor data storage
4GB ring buffer of 8GB eMMC

Table 6: Storage Capacity

Please provide the text you'd like me to translate.

WARNING!

  • Risk of malfunction
  • Risk of fire
  • Risk of explosion
  • Risk of electric shock

Do not operate the :modul II in water, in humid environments, in aggressive, flammable or explosive atmospheres, or under vibration. Due to the self-heating of the device, it must be ensured that the ambient temperature does not exceed 40°C. If this cannot be guaranteed, a ventilated or air-conditioned enclosure must be used.

Ambient conditions
Temperature range Operation -20…40 °C
Storage -40…45 °C
Transport -40…45°C
Relative humidity ≤ 90%, non-condensing
Protection class IP 20/ DIN EN 60529

Table 7: Ambient conditions

Please provide the text you'd like me to translate. Customer Service

de-smartplastics-service@igus.net
+49 (0) 2203 9649 9806

Technical support for igus® smart plastics

Documentation/FW

https://www.igus.de/info/i-sense-modul-2

Download of manuals, FW updates and certificates