igus® smart plastics
i.Sense¶

Mechanical Specifications¶
Technical Data¶
| Mechanical Specifications | |
|---|---|
| D x W x H in millimeters incl. connectors & fasteners |
110 x 31 x 125 mm |
| Weight in grams |
Approx. 120 g |
| Mounting / Installation |
TS35 DIN rail in grounded metal control cabinets |
| Color |
Black |
| Connectable conductor cross-section |
0.25…1.5 mm2 (uninsulated ferrules) 0.25…0.75 mm² (insulated ferrules) 0.25…1.5 mm² (without ferrule) |
Table 3: Mechanical Specifications
CAUTION!
- Risk of destruction
An operating voltage that exceeds the voltage specified in the technical data will destroy the . Select an operating voltage that is within the voltage range specified in the technical data.
Please provide the text you'd like me to translate.
| Electrical Specifications | |
| --- | --- |
| Power supply (terminal X7)
| 24V DC (1A max.)
|
| Power supply potential-free contacts (terminal X4)
| 24V DC (0.3A max.)
|
| Output voltage (terminal X1 and X2)
| 5V DC
|
| Output voltage (terminal X3)
| 5V DC (0.5A max.)
|
| Output voltage (terminal X5 and X6)
| 24V DC
|
| Residual ripple | 100mV pp |
Table 4: Electrical Specifications
| Interfaces | |
|---|---|
| UART |
5V (0.5A max.) Output, 115200 baud, 8N1, no parity |
| Service UART (3.5mm jack) |
3.3V Input, 115200 baud, 8N1, no parity |
| RS-485 |
proprietary |
| Bluetooth |
4.0 dual mode |
| WLAN |
802.11b/g/n |
| Ethernet |
100 Mbit/s |
Table 5: Interfaces
| Storage Capacity | |
|---|---|
| Sensor data storage |
4GB ring buffer of 8GB eMMC |
Table 6: Storage Capacity
Please provide the text you'd like me to translate.
WARNING!
- Risk of malfunction
- Risk of fire
- Risk of explosion
- Risk of electric shock
Do not operate the :modul II in water, in humid environments, in aggressive, flammable or explosive atmospheres, or under vibration. Due to the self-heating of the device, it must be ensured that the ambient temperature does not exceed 40°C. If this cannot be guaranteed, a ventilated or air-conditioned enclosure must be used.
| Ambient conditions | ||
|---|---|---|
| Temperature range | Operation | -20…40 °C |
| Storage | -40…45 °C | |
| Transport | -40…45°C | |
| Relative humidity | ≤ 90%, non-condensing | |
| Protection class | IP 20/ DIN EN 60529 |
Table 7: Ambient conditions
Please provide the text you'd like me to translate. Customer Service
de-smartplastics-service@igus.net
+49 (0) 2203 9649 9806
Technical support for igus® smart plastics
Documentation/FW
https://www.igus.de/info/i-sense-modul-2
Download of manuals, FW updates and certificates
Website smart Plastics
https://www.igus.de/info/vorausschauende-wartung-smart-plastics
Option to order sensors, processing units and further accessories
Contact
+49 2203 9649-9507
Legal Notice
© 2026
All rights reserved by
igus® SE & Co. KG
Spicher Str. 1a
51147 Cologne